Biomass CHP Neufahrn
| Systems data | ||||
| Fuel technology: air-cooled pusher grate Heat input: 21MW Fuel: biomass, waste wood S.H. Steam generated: 23,3 t/h S.H. Steam temperature: 430°C S.H. Steam pressure: 55 bar | ||||
| Work carried out + Production of inspection schedules + Coordination of various external companies required for the inspection + Manufacture and supply of various expendable parts + Routine checks on the whole system, for example: | ![]() | |||
| > Visual check on fuel feed > Grate check > Check on lining > Inspection of biomass boiler on flue gas side > Check on ash discharge | ||||
| + Maintenance work on grate and grate drive + Wall strength measurements on the superheater and eco-bundles + Boiler cleaning + Maintenance work on the lining incl. seam maintenance + Replacement of worn out eco-arches + Replacement of worn out superheater pipes + Fittings service + Production of a boiler status report incl. wall strength records and recommended further measures | ||||





Service / Example Half-year revision